Fibromyalgia - Pathology
Minerals -
updated: 11 August 2009
The relationship between serum trace element levels and clinical parameters in patients with fibromyalgia
Rheumatol Int. 2008 Sep;28(11):1117-21
Sendur OF, Tastaban E, Turan Y, Ulman C.
We examined the association between serum trace elements and clinical findings such as number of sensitive tender points, severity of fatigue and functional status in patients with fibromyalgia (FM). Thirty-two patients diagnosed as having FM according to the ACR 1990 criteria and 32 normal healthy controls (NHC) were included in this study. The demographic data, disease duration, number of tender points and accompanying symptoms (fatigue, sleep disorders, headache, paresthesia, irritable bowel syndrome, sicca symptoms, Raynaud's phenomena) of the patients were noted. Visual analog scale (10 cm) was implemented to estimate daily severity of pain and fatigue. Fibromyalgia impact questionnaire was used for functional assessment. Serum selenium (microg/dL) and serum zinc (microg/dL) levels were measured by atomic absorption spectrometer. Serum magnesium (mmol/L) level was measured by the original kits of Abbott Aeroset auto-analyzer. The mean age of patients in FM group and NHC were calculated as 42.9 (SD = 7.7) years and 41.3 (SD = 9.7) years, respectively. Serum levels of zinc (P = 0.001) and magnesium (P = 0.002) were significantly decreased by FM groups, whereas there was no considerable difference with selenium levels of both groups (P > 0.05). Association between serum zinc level and number of tender points (P = 0.008) and that between fatigue and magnesium level (P = 0.003) was found as meaningful. According to the results of this study, it was asserted that serum magnesium and zinc levels may play an important role in the pathophysiology of FM.
Publication Types:
Online - Abstract
Selenium status in fibromyalgia
Toxicol Lett. 1998 Aug;96-97:177-80
Reinhard P, Schweinsberg F, Wernet D, Kötter I.
Fibromyalgia (FM) is a chronic musculoskeletal pain syndrome of unknown etiology. The serum concentration of selenium (Se) was measured in 68 consecutive patients (nine male, mean age: 47 years; 59 female, mean age 49 years) with FM. The age- and sex-matched control group included 97 female healthy blood donors (mean age 46 years). The method is based on high-performance liquid chromatography (HPLC) involving detection of the fluorescent diaminonaphthalene (DAN) derivate of selenite. There was a statistical significant difference (P < 0.05) in serum Se between control (median 77 microg/l; range: 50-118 microg/l) and patients (median 71 microg/l; range: 39-154 microg/l) groups in the region of Tübingen, Germany.
Publication Types:
Online - Abstract
Publication Types:
|